RegFlo RF100 Series pressure and flow instruments are devices which measure and archive flow and pressure data. The Type RF110 instrument is used as a standalone pressure recorder. The Type RF100 instrument is mounted on a regulator, such as a Type EZR and can also estimate flow rates as well as record valve plug travel. Other parameters such as minimum and maximum values are also stored. Alarms may be configured to signal abnormal or emergency conditions.
RegFlo Facts
News Release
Photos
RF100 Flow Recorder
The RegFlo Type RF100 instrument measures valve plug travel, inlet pressure, and outlet pressure. A third pressure sensor is available as an option to measure an additional auxiliary pressure. An algorithm estimates the flow through the regulator and archives pressure, travel, and flow data in history. It also records other parameters such as battery voltage, minimums and maximum values, etc. Alarms may be configured to signal abnormal or emergency conditions.
RF110 Electronic Pressure Recorder (EPR)

The RegFlo Type RF110 Instrument is used as a standalone pressure recorder. It is the same as the Type RF100 except it is mounted remotely from the regulator and does not measure regulator travel or estimate flow rates. Pressures are piped to the unit and are measured and archived in history. Up to 3 pressure sensors may be installed. Other parameters such as battery output, and minimum and maximum values are also stored. Alarms may be configured to signal abnormal or emergency conditions.
Security
15 users with passwords and 3 levels of access
Environmental
Operating Temperature: -40°F to 167°F (-40° to 75°C)
Storage Temperature: -58°F to 185°F (-50° to 85°C)
Operating Humidity: 5% to 95% non-condensing
Vibration: Meets SAMA PMC 31.1
Electromagnetic Interference: Designed to meet requirements of IEC 61326 Electrical Equipment for Measurement, Control, and Laboratory Use
Radiated Emissions: FCC Part 15 Class A
Note: The pressure / temperature limits and any applicable standard or code limitation should not be exceeded.
Daily Log
35 days of daily values (average, accumulated, minimum and maximum)
Sample Intervals
1, 10 and 30 seconds; 1, 2, 5, 10, and 30 minutes
Diagnostics
Board Temperature, Power Input, Logic/Battery Voltage
Communication Ports
Operator Interface: RS-232 (RX, TX, RTS); ROC protocol only
COM1: RS-485; ROC and ModBus protocol
COM2 (Optional): RS-232 or V-22 BIS Modem; ROC and ModBus protocol
Approvals
CSA Class 1, Division 1, Explosion-Proof, Gas Groups C and D; Class 1, Division 2, Nonincindive Groups C and D; Certified to Canadian and U.S. Standards
Additional Technical Data
For additional technical information,
contact your local Sales Office or refer to technical documentation.