Emerson Process Management Website Home Emerson Corporate BusinessEmerson Corporate WebsiteSearch Emerson Corporate  WebsiteEmerson Corporate BusinessesEmerson Corporate Investor Relations
Search Emerson Process Management WebsiteEmerson Process Management PlantWebEmerson Process Management Industry CentersEmerson Process Management News & EventsEmerson Process Management ContactsEmerson Process Management Global Presence
Email:

Password:
  
Forgot Your Password?
Our Home Pages

My Page

About Us

Products/Literature

Pressurized Equipment Directive (PED)   

Support/Locator/Training

RFQ/Drawings

Technical Reference

What's New

Site Map

My Help

Order Application Guide(s)

To order Application Guide(s), click on image.

For More
Information Call

Within the US:
1-800-558-5853

Outside the US:
1-972-548-3574

Fax:
1-972-547-3712

Email:

Write:
Fisher Controls Information Center
P.O. Box 8004
McKinney, TX 75069-8004


  | Request For Quotes | Download Drawings | Search | Log In |
www.emersonprocess.com/regulators
Engineered Pressure and Flow Control Solutions

Y690A Series Tank Blanketing Valve

Related Information
To view/download available documents, select appropriate category(s):
Bulletin
Flier
Instruction Manual
PED Installation Guides
Schematics


Search: Use this feature to find other type/product information.


Enter a type/product number and select "Go"


Y690A Series Gas Blanketing Valve

The Y690A Series Gas Blanketing Regulator System reduces a high-pressure gas, such as nitrogen, to maintain a protective environment above any liquid stored in a tank or vessel. The regulator system replaces the volume of vapors with a volume of blanketing gas to prevent the internal vessel pressure from decreasing, when liquid is being pumped out or when the vessel is suddenly cooled, causing vapors to contract. In both cases a slight positive vessel pressure prevents outside, air, moisture and other contaminants from entering the vessel. The Type Y690A is a direct-operated regulator used for accurate pressure control on very low pressure blanketing systems. Downstream pressure is sensed through a pitot tube installed in the lower casing of the regulator, thus no external control line is required. The Type Y690AM uses a control line to more accurately control the pressure if the regulator is mounted away from the tank.

For your Total Tank Management solutions, here!

If you would like access to downloadable CAD drawings, please login or register.
Features
  • Easy Conversion Between Constructions
  • Sour Gas Service Capability
  • Inlet Pressure Equals Outlet Pressure
  • Corrosion Resistance
  • Multiple Applications
Back to Top
Body Sizes
3/4 or 1-inch (DN 20 or 25)
Back to Top
Maximum Allowable Inlet Pressure
150 psig (10,3 bar)
Back to Top
Maximum Outlet Pressure (Casing)
150 psig (10,3 bar)
Back to Top
Maximum Emergency Outlet Pressure to Avoid Internal Parts Damage
150 psig (10,3 bar)
Back to Top
Material Temperature Capabilities
Nitrile (NBR): -20 to 180º F (-29 to 82ºC)
Fluoroelastomer (FKM): 40 to 300ºF (4 to 149ºC)
Ethylenepropylene (EPDM): -20 to 275ºF (-29 to 135ºC)
Perfluoroelastomer(FFKM): -20 to 300ºF (-29 to 149C)
Back to Top
Pressure Setting Adjustment
Adjusting
Back to Top
Spring Case Connection
1/4-inch NPT
Back to Top
Diaphragm Case Connection
1/2-inch NPT
Back to Top
Approximate Weight
19 pounds (8,62 kg)
Back to Top
Additional Technical Data
For additional technical information, contact your Local Sales Office or refer to technical documentation.
Back to Top

Contacts:
    Telephone     Email     Write    

Within the US:
1-800-558-5853

Outside the US:
1-972-548-3574

Fax:
1-972-547-3712

Emerson Regulator Division Information Center
P.O. Box 8004
McKinney, TX 75069-8004




Send comments to:

 